repeat">
Troposphaira Technologies Llp
Troposphaira Technologies Llp
Moshi, Pimpri Chinchwad, Pune, Maharashtra
GST No. 27AARFT0112H1Z9
08046034029 82% Response Rate
Send E-mail

MODBUS Gateway

Our product range includes a wide range of ocpp to modbus tcp & rtu server gateway, m-bus to modbus tcp & rtu server gateway, knx tp to modbus tcp & rtu server application, m-bus to modbus tcp server gateway, modbus rtu to modbus tcp ip gateway and dali to modbus tcp server gateway.
Request CallBack
  • OCPP to Modbus TCP & RTU Server Gateway
  • OCPP to Modbus TCP & RTU Server Gateway
  • OCPP to Modbus TCP & RTU Server Gateway
  • OCPP to Modbus TCP & RTU Server Gateway
  • OCPP to Modbus TCP & RTU Server Gateway
OCPP to Modbus TCP & RTU Server Gateway
Get Best Quote

OCPP to Modbus TCP & RTU Server Gateway

Approx. Price: Rs 33,600 / PieceGet Latest Price
Product Brochure
Product Details:
InterfaceEthernet
Serial Port Number2
Throughput100 Mbps
Modbus TypeModbus TCP/IP
Number Of Ports2
Usage/ApplicationIndustrial
Dimensions (with ears)93x53x58 mm
IP Access methodIntesis MAPS
Model Name/NumberINMBSOCP0200100
Ethernet Ports1 Port
OCPP to Modbus TCP & RTU Server GatewayIntegrate Electric Vehicles Charging points based on OCPP 1.6 with any Modbus RTU or TCP controller or connect the chargers to an external OCPP Central System (CS) and monitor them via Modbus. This gateway offers 2 type of OCPP functionalities configurable in MAPS tool:
- BMS Central System: The gateway makes accessible advanced operations of the Charging points from a Modbus PLC, making the BMS the Central System of the EV charging operation.
- External OCPP central system: The gateway acts as a bridge between an external OCPP CS and the OCPP chargers, allowing to monitor metering and status information of the connected chargers.
FEATURES
Support for OCPP 1.6 JSONSupport for Modbus RTU and TCPFlexible Modbus configuration (Baudrate, Data type)OCPP Scan to search Chargers in the networkFix Modbus register mapOCPP operations supported in BMS CS mode:-Authorize, RemoteStart/Stop Transaction, Start/StopTransaction, Local list management, HeartBeat, MeterValues​, Reservation and Smart Charging OperationsOCPP readings supported in External CS mode:- Charger info, availability and MeterValuesReduced dimensions, compact housingUL certified

Yes! I am Interested
Watch Video
Request CallBack
  • M-BUS to Modbus TCP & RTU Server Gateway
  • M-BUS to Modbus TCP & RTU Server Gateway
  • M-BUS to Modbus TCP & RTU Server Gateway
  • M-BUS to Modbus TCP & RTU Server Gateway
  • M-BUS to Modbus TCP & RTU Server Gateway
M-BUS to Modbus TCP & RTU Server Gateway
Get Best Quote

M-BUS to Modbus TCP & RTU Server Gateway

Approx. Price: Rs 53,600 / PieceGet Latest Price
Product Brochure
Product Details:
Terminator for RS-485
Number Of Ports2
Usage/ApplicationIndustrial
Network TypeTCP/IP
Model Name/NumberM-BUS to Modbus TCP & RTU Server Gateway - 20 devices
Power Supply24VDC
Ethernet Ports1
This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features. Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, a seamless integration with any Modbus BMS or controller it is guaranteed.The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available projecttemplates or to import any created/exported project template on your computer.

INMBSMEB0100000-M-BUS to Modbus TCP & RTU Server Gateway - 10 devicesINMBSMEB0200000-M-BUS to Modbus TCP & RTU Server Gateway - 20 devicesINMBSMEB0600000-M-BUS to Modbus TCP & RTU Server Gateway - 60 devicesINMBSMEB1200000-M-BUS to Modbus TCP & RTU Server Gateway - 120 devices
INMBSMEB0200100-M-BUS to Modbus TCP Gateway -20 devicesINMBSMEB0500100-M-BUS to Modbus TCP Gateway -50 devices

Additional Information:
  • Delivery Time: 4 weeks
Yes! I am Interested
Watch Video
Request CallBack
  • KNX TP to Modbus TCP & RTU Server Application
  • KNX TP to Modbus TCP & RTU Server Application
  • KNX TP to Modbus TCP & RTU Server Application
  • KNX TP to Modbus TCP & RTU Server Application
  • KNX TP to Modbus TCP & RTU Server Application
KNX TP to Modbus TCP & RTU Server Application
Get Best Quote

KNX TP to Modbus TCP & RTU Server Application

Approx. Price: Rs 41,600 / PieceGet Latest Price
Product Brochure
Product Details:
InterfaceEthernet
Serial Port Number2
Throughput100 Mbps
Modbus TypeModbus TCP/IP
Dimensions (with ears)99 x 88 x 56 mm
Backplane Current Load180mA
Ethernet Ports1 Port

This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features.

Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, a seamless integration with any Modbus BMS or controller it is guaranteed.

The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer.

IN701KNX1000000 Intesis protocol translator with KNX, Serial and IP support - 100 points

IN701KNX2500000 Intesis protocol translator with KNX, Serial and IP support - 250 points

IN701KNX6000000 Intesis protocol translator with KNX, Serial and IP support - 600 points

IN701KNX1K20000 Intesis protocol translator with KNX, Serial and IP support - 1200 points

IN701KNX3K00000 Intesis protocol translator with KNX, Serial and IP support - 3000 points

 


Yes! I am Interested
Watch Video
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
  • M-BUS to Modbus TCP Server Gateway
M-BUS to Modbus TCP Server Gateway
Get Best Quote

M-BUS to Modbus TCP Server Gateway

Approx. Price: Rs 38,500 / PieceGet Latest Price
Product Brochure
Product Details:
InterfaceEthernet
Serial Port Number1
Throughput1 Gbps
Modbus TypeModbus TCP/IP
Usage/ApplicationIOT
Dimensions (with ears)100 x 60 x 70mm
IP Access methodIntesis MAPS
Model Name/NumberINMBSMEB0200100
ColorLight grey. RAL 7035
Ethernet Ports1 Port
Power Supply24VDC
Operating Temperature0-60 Deg.C

Integrate any M-Bus device with Modbus. The aim of this integration is to make accessible M-Bus devices, its registers and resources from a Modbus-based control system or device as if it was a part of the own Modbus system and vice-versa.

FEATURESUL Listed.Scan: Automatic identification of M-Bus devices (meter detection) and registers discovery.Embedded M-Bus level converter.Up to 5 TCP clients (incoming sockets) are supported.Supports Modbus TCP physical layer.Configuration through IP (Console) port.Easy integration with Intesis MAPS.Automatic updates for both Intesis MAPS and the interface’s firmware.

Yes! I am Interested
Watch Video
Request CallBack
  • MODBUS RTU to MODBUS TCP IP GATEWAY
  • MODBUS RTU to MODBUS TCP IP GATEWAY
  • MODBUS RTU to MODBUS TCP IP GATEWAY
  • MODBUS RTU to MODBUS TCP IP GATEWAY
MODBUS RTU to MODBUS TCP IP GATEWAY
Get Best Quote

MODBUS RTU to MODBUS TCP IP GATEWAY

Approx. Price: Rs 8,500 / PieceGet Latest Price
Product Brochure
Product Details:
Minimum Order Quantity1 Piece
Number Of PortsOne
Usage/ApplicationIOT
Network TypeTCP
Compatible BrandTROPOSPHAIRA
Power Supply5-25 VDC
Ethernet Ports1x Ethernet Port - 10/100 Mbps
Baud Rate115200
Terminator for RS-485
Country of OriginMade in India

Hardware Specifications
 
  Power:
  5 - 24 V DC , 200mA @ 24VDC
  Reverse polarity protection.
 
  Communication:
  1x Ethernet Port - 10/100 Mbps
  Modbus TCP- Modbus Slave for host device.
  Web Interface for easy configuration
 
  1x RS485 Ports (Optically Isolated)
  2x RS485 Ports (Optically Isolated)
  Modbus RTU- Modbus Master for connecting
  32 slaves over RS485.
 
  Baud Rate Supports : 4800, 9600, 19200, 38400, 57600, 115200
 
  Mounting: DIN EN60715 Rail Mount. 
 
  Default IP :192.168.1.254
 
  Environmental:
  Operating Temperature: -20 to 70 ⁰C
  Relative Humidity: 5-95% rH, non-condensing.

  Mechanical Dimensions:
  70mm L x 70 mm W x 110 mm H
 
         Enclosure:
   Grey / High impact polycarbonate


Additional Information:
  • Production Capacity: 200 per month
Yes! I am Interested
Request CallBack
  • DALI to Modbus TCP Server Gateway
  • DALI to Modbus TCP Server Gateway
  • DALI to Modbus TCP Server Gateway
  • DALI to Modbus TCP Server Gateway
  • DALI to Modbus TCP Server Gateway
DALI to Modbus TCP Server Gateway
Ask For Price

DALI to Modbus TCP Server Gateway

Product Price : Get Latest Price
Product Brochure
Product Details:
Number Of Ports1
Dimensions (with ears)Net dimensions (dxwxh): 88x106x56 mm
Usage/ApplicationIOT
Model Name/NumberINMBSDAL0640500 1 DALI channel)
ColorLight Grey. RAL 7035
Power Supply24VDC/AC +/-10% 6W(250mA)
Operating Temperature0 DegreeC to +50 DegreeC
Ethernet Ports1 x Ethernet 10/100 Mbps RJ45
Relative Humidity5 to 95%, no condensation
DALI to Modbus TCP Server Gateway

Integrate any DALI/DALI-2 driver and DALI-2 light sensor, or occupancy sensor with a Modbus BMS or any Modbus TCP controller. The aim of this integration is to make DALI devices and its data and resources accessible from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.

FEATURES

  • UL Certified
  • DALI-2 Certified
  • Support for up to 5 simultaneous Modbus TCP Clients
  • Support for DALI & DALI-2 drivers & DALI-2 Input devices including: Push buttons, Absolute inputs, Occupancy and Light sensors
  • Integrated DALI power supply
  • 1 DALI channel
  • Up to 64 drivers/ballasts + 64* DALI-2 input devices (sensors, push buttons or absolute inputs). *See manual for details
  • Easy integration & DALI commissioning with Intesis MAPS
  • Up to 10000 signals in total and 230mA current guaranteed

Yes! I am Interested
Watch Video
Save time! Get the Best Deal

*Your information is safe with us.

Request CallBack
  • BACnet IP & MS/TP Client to Modbus TCP & RTU
  • BACnet IP & MS/TP Client to Modbus TCP & RTU
  • BACnet IP & MS/TP Client to Modbus TCP & RTU
  • BACnet IP & MS/TP Client to Modbus TCP & RTU
  • BACnet IP & MS/TP Client to Modbus TCP & RTU
  • BACnet IP & MS/TP Client to Modbus TCP & RTU
  • BACnet IP & MS/TP Client to Modbus TCP & RTU
  • BACnet IP & MS/TP Client to Modbus TCP & RTU
BACnet IP & MS/TP Client to Modbus TCP & RTU
Ask For Price

BACnet IP & MS/TP Client to Modbus TCP & RTU

Product Price : Get Latest Price
Product Brochure
Product Details:
InterfaceEthernet
Serial Port Number2
Throughput100 Mbps
Modbus TypeModbus TCP/IP
IP Access methodMAPS
Ethernet Ports1 Port

Integrate any BACnet MS/TP or BACnet IP server device, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible BACnet objects data and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.

FEATURES

  • UL Certified
  • BTL Certified
  • Support for up to 5 simultaneous Modbus TCP Clients
  • Both Modbus RTU & Modbus TCP
  • Both BACnet IP and MS/TP supported
  • Possibility to scan for BACnet devices with BACnet Explorer
  • Easy integration & updates with Intesis MAPS

Yes! I am Interested
Watch Video
Request CallBack
  • Daikin VRV and Sky systems to Modbus RTU Interface
  • Daikin VRV and Sky systems to Modbus RTU Interface
  • Daikin VRV and Sky systems to Modbus RTU Interface
  • Daikin VRV and Sky systems to Modbus RTU Interface
Daikin VRV and Sky systems to Modbus RTU Interface
Ask For Price

Daikin VRV and Sky systems to Modbus RTU Interface

Product Price : Get Latest Price
Product Brochure
Product Details:
InterfaceRS 485
Serial Port Number1
Modbus TypeModbus RTU
IP Access methodMAPS
Daikin VRV and Sky systems to Modbus RTU InterfaceThe Daikin-Modbus gateway allows fully bi-directional communication between Daikin VRV and Sky systems and Modbus RTU (RS-485) networks.
FEATURES
Modbus RTU (EIA485) slave device.Configuration from both onboard DIP-switches and Modbus RTU.Quick and easy installation (plug and set the DP-SW).External power not required.Simultaneous control of the AC unit by the IR remote controller and by Modbus RTU.Reduced dimensions 93 x 53 x 58 mm.Mountable on DIN rail, wall, or even inside the indoor unit in some models of AC.Window contact function allows energy savings. Costs related to HVAC systems in a building are one of the highest and this type of functions allow to reduce them.Total control and monitoring of the AC unit from Modbus RTU, including AC unit’s internal variables, running hours counter (for filter maintenance control) and error indication.

Yes! I am Interested
X