Interface | Ethernet |
Serial Port Number | 2 |
Throughput | 100 Mbps |
Modbus Type | Modbus TCP/IP |
Number Of Ports | 2 |
Usage/Application | Industrial |
Dimensions (with ears) | 93x53x58 mm |
IP Access method | Intesis MAPS |
Model Name/Number | INMBSOCP0200100 |
Ethernet Ports | 1 Port |
Terminator for RS- | 485 |
Number Of Ports | 2 |
Usage/Application | Industrial |
Network Type | TCP/IP |
Model Name/Number | M-BUS to Modbus TCP & RTU Server Gateway - 20 devices |
Power Supply | 24VDC |
Ethernet Ports | 1 |
Interface | Ethernet |
Serial Port Number | 2 |
Throughput | 100 Mbps |
Modbus Type | Modbus TCP/IP |
Dimensions (with ears) | 99 x 88 x 56 mm |
Backplane Current Load | 180mA |
Ethernet Ports | 1 Port |
This bidirectional gateway provides a straightforward and fast integration thanks to its unique onboard features.
Thanks to its support for both Modbus RTU and TCP, with the possibility to work together at the same time, a seamless integration with any Modbus BMS or controller it is guaranteed.
The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device. Also, it will be able to download all the available project templates or to import any created/exported project template on your computer.
IN701KNX1000000 Intesis protocol translator with KNX, Serial and IP support - 100 points
IN701KNX2500000 Intesis protocol translator with KNX, Serial and IP support - 250 points
IN701KNX6000000 Intesis protocol translator with KNX, Serial and IP support - 600 points
IN701KNX1K20000 Intesis protocol translator with KNX, Serial and IP support - 1200 points
IN701KNX3K00000 Intesis protocol translator with KNX, Serial and IP support - 3000 points
*Your information is safe with us.
Interface | Ethernet |
Serial Port Number | 1 |
Throughput | 1 Gbps |
Modbus Type | Modbus TCP/IP |
Usage/Application | IOT |
Dimensions (with ears) | 100 x 60 x 70mm |
IP Access method | Intesis MAPS |
Model Name/Number | INMBSMEB0200100 |
Color | Light grey. RAL 7035 |
Ethernet Ports | 1 Port |
Power Supply | 24VDC |
Operating Temperature | 0-60 Deg.C |
Integrate any M-Bus device with Modbus. The aim of this integration is to make accessible M-Bus devices, its registers and resources from a Modbus-based control system or device as if it was a part of the own Modbus system and vice-versa.
FEATURESUL Listed.Scan: Automatic identification of M-Bus devices (meter detection) and registers discovery.Embedded M-Bus level converter.Up to 5 TCP clients (incoming sockets) are supported.Supports Modbus TCP physical layer.Configuration through IP (Console) port.Easy integration with Intesis MAPS.Automatic updates for both Intesis MAPS and the interface’s firmware.Minimum Order Quantity | 1 Piece |
Number Of Ports | One |
Usage/Application | IOT |
Network Type | TCP |
Compatible Brand | TROPOSPHAIRA |
Power Supply | 5-25 VDC |
Ethernet Ports | 1x Ethernet Port - 10/100 Mbps |
Baud Rate | 115200 |
Terminator for RS- | 485 |
Country of Origin | Made in India |
Hardware Specifications
Power:
5 - 24 V DC , 200mA @ 24VDC
Reverse polarity protection.
Communication:
1x Ethernet Port - 10/100 Mbps
Modbus TCP- Modbus Slave for host device.
Web Interface for easy configuration
1x RS485 Ports (Optically Isolated)
2x RS485 Ports (Optically Isolated)
Modbus RTU- Modbus Master for connecting
32 slaves over RS485.
Baud Rate Supports : 4800, 9600, 19200, 38400, 57600, 115200
Mounting: DIN EN60715 Rail Mount.
Default IP :192.168.1.254
Environmental:
Operating Temperature: -20 to 70 ⁰C
Relative Humidity: 5-95% rH, non-condensing.
—
Mechanical Dimensions:
70mm L x 70 mm W x 110 mm H
Enclosure:
Grey / High impact polycarbonate
Number Of Ports | 1 |
Dimensions (with ears) | Net dimensions (dxwxh): 88x106x56 mm |
Usage/Application | IOT |
Model Name/Number | INMBSDAL0640500 1 DALI channel) |
Color | Light Grey. RAL 7035 |
Power Supply | 24VDC/AC +/-10% 6W(250mA) |
Operating Temperature | 0 DegreeC to +50 DegreeC |
Ethernet Ports | 1 x Ethernet 10/100 Mbps RJ45 |
Relative Humidity | 5 to 95%, no condensation |
Integrate any DALI/DALI-2 driver and DALI-2 light sensor, or occupancy sensor with a Modbus BMS or any Modbus TCP controller. The aim of this integration is to make DALI devices and its data and resources accessible from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.
FEATURES
*Your information is safe with us.
Interface | Ethernet |
Serial Port Number | 2 |
Throughput | 100 Mbps |
Modbus Type | Modbus TCP/IP |
IP Access method | MAPS |
Ethernet Ports | 1 Port |
Integrate any BACnet MS/TP or BACnet IP server device, with a Modbus BMS or any Modbus TCP or Modbus RTU controller. The aim of this integration is to make accessible BACnet objects data and resources from a Modbus based control system or device, as if it was a part of the own Modbus system and vice-versa.
FEATURES
Interface | RS 485 |
Serial Port Number | 1 |
Modbus Type | Modbus RTU |
IP Access method | MAPS |